A/C-Heater System - Manual: Specifications
A/C SYSTEM SPECIFICATIONS
| Application | Specification | |
|---|---|---|
| System | R-134a with Thermostatic Expansion Valve | |
| Compressor | Denso 10PA17 | |
| Freeze Up Control | Mechanical Clutch Cycling Switch | |
| Internal Near Evaporator | ||
| Off | 34°F | |
| ON | 40°F | |
| Dual Pressure Cutout Switch On Receiver-Drier | ||
| Low psi Control | Opens < 17.56-23.24 psi - resets 36.7 psi | |
| High psi Control | opens > 470 psi - resets < 270-330 psi | |
| Control Head | Manual Type | |
| Heat/Defrost | Vacuum | |
| Water Valve | Cable | |
| Vent Door | Vacuum | |
| Recirc Duct | Vacuum | |
| Blower Motor | ||
| Resistor Block | Control Head Switched | |
| Cooling Fan | 2 Speed Electric | |
| Clutch | ||
| Control | Relay - PCM | |
| Draw | 2-3.7 amps @ 12V | |
| Gap | .014-.026" | |
| DRBIII® | ||
| Reads | TPS, RPM, A/C Switch Test | |
| Actuators | Fan & Clutch Relays | |