Center Motor
- Remove switch from mounting position and disconnect switch from harness. See SWITCH R & I under REMOVAL & INSTALLATION.
- Connect a jumper wire between terminals No. 2 and 9. See Figure . Connect second jumper wire between terminals No. 1 and 10. If motor does not operated, reverse jumpers (No. 2 to No. 10, and No. 1 to No. 9). If motor still does not operate check wiring between switch connector and motor assembly. If wiring is good, replace motor assembly.