Battery Temperature Sensor Calibration Check
- This checks battery temperature sensor. Connect DRB-II to engine harness connector, Sensor Test Mode 01. Display reading on DRB-II should be between .2-3.0 volts.
- Check for battery drain-down condition. Put the system in Engine Running Test Mode 61. Divide reading on display by 10. Display on DRB-II should be 2-5 volts. If not as specified, replace SMEC.