Rear Motor
Connect a jumper lead between RED wire terminal in center section of connector and either the RED-BLU or YEL-BLU terminal in rear connector section. Connect another jumper between the BLK wire terminal in center section and open connection in rear section. If motor does not operate, reverse jumpers in rear section. If motor still does not operate, either harness or three motor assembly should be replaced.