Front Motor
Connect a jumper lead between RED wire terminal in center section of connector and either the RED-GREEN or YELLOW-GREEN connection in front section (see illustration). Connect another jumper wire between black wire terminal in center section and open connection in front section. If motor does not operate, reverse jumpers in front section. If motor still does not operate, either harness or complete three motor assembly should be replaced.