Automatic Choke Setting: Notes
NOTE:
Under normal servicing do NOT change the setting or disassemble the control unit. If however, the setting has been disturbed, reset as follows: Loosen locknut and turn shaft with screwdriver until index mark on disc is in alignment with correct mark on the frame (See Below).
| 318" | (Carter 2-Bbl.) | Index |
| (Rochester 2-Bbl.) | No Setting | |
| 340" | (Carter 4-Bbl.) | 2 Rich |
| (3 2-Bbl.) | Index | |
| 360" | 2 Rich | |
| 383" | 2 Rich | |
| 440" | 2 Rich | |
| 426" | No Setting | |