LEMON Manuals: Even more car manuals for everyone
Home >> Dodge and Ram >> 1968 >> P200 Base, Not Available Trans >> Repair and Diagnosis >> Maintenance >> Procedures >> Engine Cooling Systems >> CHRYSLER Corp.

CHRYSLER Corp.

COOLING SYSTEM CAPACITY

Application (1)Quarts
1965  
  170" 12
  225"  
    A100 13
    All Others (2) 13
  273" 17
  318" (2) 20
1966  
  170" 12
  225"  
    A100 13
    All Others (2) 13
  273" 17
  318" & 383" (2) 16.5
1967  
  170" 12.5
  225"  
    A100 14.5
    All Others 12
  318"  
    A100 19
    All Others 16
  383" 15
1968  
  170" 12.5
  225"  
    A100 14.5
    All Others 14
  318"  
    A100 19
    Motor Home (2) 22
    All Others 18
  383" 16
1969  
  170" 12.5
  225"  
    A100 14.5
    D300, W300 14
    All Others (3) 13
  318"  
    A100 19
    W300 (3) 18
    Motor Home (2) 22
    All Others (4) 18
  383" 17
1970  
  170" 12.5
  225"  
    A100 14.5
    "B" Models (5) 13
    All Others (3) 13
  318"  
    A100 19
    "B" Models (6)17
    Motor Home (2) 22
    W300 (3) 18
    All Others (4) 18
  360"  
    "B" Models (4) 17
  383" 17
  413" Motor Home (2) 27
1971  
  225"  
    "B" Models (5) 13
    All Others (3) 13
  318"  
    "B" Models (6)17
    W300 (3) 18
    Motor Home (2) 22
    All Others (4) 18
  360"  
    "B" Models (4) 17
  383" 17
  413" Motor Home (2) 27
1972  
  225"  
    "B" Models (5) 13
    D100, D200 (6)13
    W100, W200 (7)13
    All Others 14
  318"  
    "B" Models (6)17
    D100 (8)17
    W100 (9) 17
    All Others (10) 17
  318"-3 Motor Home (2)(14) 22
  360"  
    "B" Models (4) 17
    All Others (4) 16
  400" (6)16
  413" Motor Home (2)(14) 27
1973  
  225"  
    W100, W200 (6)13
    D300, W300 14
    All Others (5) 13
  318"  
    "B" Models (6)17
    D100, W100 17
    All Others (11) 17
  318"-3 Motor Home (2)(14) 22
  360" (4) 16
  400"  
    D100, D200 (6)16
    D300 (4) 17
  413" Motor Home (2)(14) 27
  440"  
    D100 (6)(12) 16
    D200, D300 (6)(12) 17
1974  
  225"  
    W100, W200 (6)13
    D300, W300 14
    All Other Models (5) 13
  318"  
    B300 & PB300 W/Auto. Trans. (13) 18
    "B" & "PB" Models (All Others) (6)17
    "AW" & "PW" Models (6)16
    D100, W100 17
    All Others Models (11) 17
  318" - 3 Motor Home (2)(14) 22
  360" (6)16
  400"  
    D100, D200 (6)16
    D300 (4) 17
  440"  
    "AW" & "PW" Models (6)16
    D200, D300 (6)(12) 17
    D100 (6)(12) 16
(1) Subtract 1 qt. if not equipped with heater. If equipped with an Auxiliary heater, add 1 qt.
(2) Does not include heater.
(3) Add 2 qts. W/Air Cond.
(4) Add 1 qt. W/Air Cond.
(5) Add 1 qt. W/Increased Cooling.
(6) Add 1 qt. W/Increased Cooling or Air Cond.
(7) Add 1 qt. W/Auto. Trans., Increased Cooling or Air Cond.
(8) Add 1 pt. W/Increased Cooling or Air Cond.
(9) Add 1 pt. W/Auto. Trans., Increased Cooling or Air Cond.
(10) Add 1 pt. W/Increased Cooling or 1 1/2 qt. W/Air Cond.
(11) Add 1 1/2 qt. W/Air Cond.
(12) Add 1 qt. W/Coolant Reserve System.
(13) Add 1 qt. W/Increased Cooling and 2 qts. W/Air Cond.
(14) Add 2 qts. W/Coolant Reserve System.
THERMOSTAT

Application (1)Initial Open (1)Full Open
1965-67    
    All Models 177-184 200
1968    
    Motor Home 182-189 205
    A100 (170") 187-194 210
    All Others 177-184 200
1969    
    Motor Home 182-189 205
    A100 (225" & 318") 177-184 200
    All Others 187-194 210
1970    
    A100 (170") 187-194 210
    A100 (225" & 318") 177-184 200
    All Others 182-189 205
1971-73    
    All Models 182-189 205
1974    
  6 Cyl. Engine    
    All Models 192-199 219
  V8 Engine    
    Motor Home 182-189 205
    D200/300 & W200/300 182-189 205
    D100 & W100 192-199 219
    "AW" & "PW" Models 192-199 219
    B100/200 318" 192-199 219
    PB100/200 318" 192-199 219
    B300 & PB300 182-189 205
(1) Specifications are in °F.
PRESSURE CAP

Application PSI
1965-67  
  A100 14
  All Others 7
1968-69  
  Motor Home 7
  All Others 14
1970-71  
  "B" Models 16
  Motor Home 7
  All Others 14
1972-74  
  All Models 16