Diagnostic Aids
Check for a poor connection or damaged PCM/ECM harness. Inspect O2S1 sensor signal circuit and ground circuit terminals for following conditions:
- Improper mating.
- Broken locks.
- Improperly formed.
- Damaged terminals.
- Poor terminal-to-wire connection.
- Damaged harness.