Sensor, Knock: Installation: 5.7L/6.4L
CAUTION:
Over or under tightening the knock sensor mounting bolts will affect knock sensor performance, possibly causing improper spark control.
NOTE:
There may be a foam strip on the bolt threads. The foam strip on the knock sensor retaining bolt threads is only used to retain the bolts to the knock sensors for manufacturing purposes. It is not used as a sealant. Do not apply any adhesive, sealant or thread locking compound to these bolts.
- Install the knock sensor (1) onto cylinder block. Tighten bolt (2) to the proper torque specification. Refer to TORQUE SPECIFICATIONS .
- Connect the knock sensor wire harness connector (5).
- Snap the heat shield (1) onto the knock sensor.
- Install the belly pan and securely tighten bolts (1).
- Connect the negative battery cable.