Valve, Short Runner: Installation: Installation
NOTE:
When the SRV actuator is removed, a new rubber O-ring seal must be installed. The old O-ring cannot be reused.
- Install a new SRV actuator rubber O-ring seal (1).
- Position the SRV actuator (2), install the retaining bolts (1) and tighten to 5 N.m (44 in. lb.).
- Install the intake manifold and throttle body as an assembly. Refer to MANIFOLD, INTAKE, INSTALLATION or MANIFOLD, INTAKE, INSTALLATION, 5.7L or MANIFOLD, INTAKE, INSTALLATION .
- Connect the negative battery cable (1).