LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2009 >> Sebring Base, 2D Convertible, ED3 >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 16 (Powertrain Control Module (Pcm) - Electrical Diagnostics - 41TE Automatic Transmission) >> DTC Troubleshooting >> P0845-2/4 Hydraulic Pressure Test >> Possible Causes

Possible Causes

WARNING: This page is about a different variant/trim than selected.
Possible Causes 
LOSS OF PRIME P0944 PRESENT
(T16) TRANSMISSION CONTROL OUTPUT CIRCUIT OPEN
(T47) 2/4 PRESSURE SIGNAL CIRCUIT OPEN
(T47) 2/4 PRESSURE SIGNAL CIRCUIT SHORTED TO GROUND
(T47) 2/4 PRESSURE SIGNAL CIRCUIT SHORTED TO VOLTAGE
TRANSMISSION SOLENOID/PRESSURE SWITCH ASSEMBLY
CONTAMINATED FLUID (TYPICALLY WATER CONTAMINATION)
VALVE BODY INTERNAL LEAKAGE
POWERTRAIN CONTROL MODULE (PCM)

Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding. See  DTC-Based Diagnostics/MODULE, Powertrain Control (PCM) - Standard Procedure  .