LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2009 >> Sebring Base, 2D Convertible, ED3 >> Repair and Diagnosis >> External Pages >> Different car >> Section 10 (Starting System (Service Information)) >> Diagnosis and Testing >> Starting System Test >> Inspection

Starting System Test: Inspection

WARNING: This page is about a different car, the 2010 Dodge Avenger and 2010 Chrysler Sebring. However, it is still accessible from the selected car via links, so may be relevant.

Before removing any unit from the starting system for repair or diagnosis, perform the following inspections:

STARTING SYSTEM DIAGNOSIS

CONDITION POSSIBLE CAUSE CORRECTION
STARTER FAILS TO ENGAGE. 1. Battery discharged or faulty. 1. Refer to BATTERY for more information. Charge or replace battery, if required.
- 2. Starting circuit wiring faulty. 2. Refer to FEED CIRCUIT RESISTANCE TEST 
- 3. Starter relay faulty. 3. Refer to RELAY TEST  . Replace relay, if necessary.
- 4. Ignition switch faulty. 4. Refer to STEERING for ignition switch test, or refer to appropriate wiring diagrams. Replace switch, if necessary.
- 5. Park/neutral position switch (auto trans) faulty or mis-adjusted. 5. Refer to appropriate park/neutral position switch test in the transaxle article for more information. Replace switch, if necessary.
- 6. Clutch interlock switch (man trans) faulty. 6. Perform clutch pedal position switch test. Replace switch, if necessary.
- 7. Starter solenoid faulty. 7. Refer to STARTER SOLENOID  solenoid test, in this article. Replace starter assembly, if necessary.
- 8. Starter assembly faulty. 8. If all other starting system components and circuits check ok, replace starter assembly.
- 9. Faulty teeth on ring gear. 9. Rotate flywheel 360°, and inspect teeth and ring gear replaced if damaged.
- 10. PCM double start override output failure. 10. Refer to appropriate PCM diagnostic in Transmission information. Check for continuity between PCM and terminal 85. Repair open circuit as required. If ok, PCM may be defective.
STARTER ENGAGES, FAILS TO TURN ENGINE. 1. Battery discharged or faulty. 1. Refer to BATTERY SYSTEM for more information. Charge or replace battery as necessary.
- 2. Starting circuit wiring faulty. 2. Refer to FEED CIRCUIT RESISTANCE TEST  and the feed circuit test in this article. Repair as necessary.
- 3. Starter assembly faulty. 3. If all other starting system components and circuits check ok, replace starter assembly.
- 4. Engine seized. 4. Refer to appropriate engine article, for diagnostic and service procedures.
- 5. Loose connection at battery, PDC (Diesel Only), TIPM, starter, or engine ground. 5. Inspect for loose connections.
- 6. Faulty teeth on ring gear. 6. Rotate flywheel 360°, and inspect teeth and ring gear replaced if damaged.
STARTER ENGAGES, SPINS OUT BEFORE ENGINE STARTS. 1. Broken teeth on starter ring gear. 1. Remove starter. Inspect ring gear and replace if necessary.
- 2. Starter assembly faulty. 2. If all other starting system components and circuits check ok, replace starter assembly.
STARTER DOES NOT DISENGAGE. 1. Starter improperly installed. 1. Install starter. Tighten starter mounting hardware to correct torque specifications.
- 2. Starter relay faulty. 2. Refer to RELAY TEST  . Replace relay, if necessary.
- 3. Ignition switch faulty. 3. Refer STEERING . Replace switch, if necessary.
- 4. Starter assembly faulty. 4. If all other starting system components and circuits check ok, replace starter assembly.
- 5. Faulty teeth on ring gear. 5. Rotate flywheel 360°, and inspect teeth and ring gear replaced if damaged.