Fuel Level Sensor - Gas (Non FFV)
Remove fuel pump module, see INSTALLATION .
- Depress retaining tab and remove the fuel pump/level sensor connector from the bottom of the fuel pump module electrical connector.
- Pull off locking wedge.
- Using a small screwdriver lift locking finger away from terminal and push level sensor and ground terminals out of connector.
- Slide level sensor out of installation channel in module.