| COWL GRILLE NOZZLE WILL NOT FLOW. |
1. Frozen nozzle. |
1. Check heated washer nozzle operation. Repair system as necessary. |
| 2. Nozzle hose not flowing. |
2. Ensure nozzle hose is not pinched, loose, broken, or disconnected. If not OK, properly route or repair nozzle hose. |
| - |
3. Nozzle or nozzle hose plugged by contamination. |
3. Clean nozzle hose of contamination. Determine source of contamination; inspect reservoir and clean system as required. |
| WASHER FLUID OUTPUT IS LOW. |
1. Partially pinched hose. |
1. Ensure washer hose is not partially pinched. If not OK, properly route hose. |
| 2. Reverse polarity to pump. |
2. Check for crossed circuity to pump. If not OK, repair circuit. |
| - |
3. Nozzle or nozzle hose plugged by contamination. |
3. Clean nozzle hose of contamination. Determine source of contamination; inspect reservoir and clean system as required. |
| COWL GRILLE NOZZLE STREAM OVERSHOOTS WINDSHIELD. |
1. Nozzle not seated in cowl grille properly |
1. Ensure nozzle is aligned and snapped in place properly. |
| 2. Nozzle jet(s) out of adjustment. |
2. Adjust nozzle jets using a safety pin. |