Standard Procedure: Removal
When disconnecting a quick-connect fitting, the retainer will remain on the fuel tube nipple.
WARNING:
Release fuel system pressure before disconnecting a quick-connect fittings. Refer to FUEL SYSTEM PRESSURE RELEASE PROCEDURE . This may result in personal injury or death.
- Release the fuel pressure. Refer to FUEL SYSTEM PRESSURE RELEASE PROCEDURE .
- Disconnect negative cable from battery or auxiliary jumper terminal.
- Squeeze retainer tabs together and pull fuel tube/quick-connect fitting assembly off of fuel tube nipple. The retainer will remain on fuel tube.