LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2007 >> 300 Base >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Communication Devices >> Electronic Control Modules (Service Information) >> Module - Antilock Brake >> Installation

Module - Antilock Brake: Installation

  1. Clean any debris off the mating surfaces of the HCU and ABM.
    CAUTION: When installing new O-rings or solenoid valve stem seals, do not use any type of lubricant.
    Fig 1: Solenoid Valve Seal
    GC0039495Courtesy of CHRYSLER LLC
  2. If the seals (1) on the solenoid valve stems (2) are not new, replace them all. Each of the solenoid valve stem seals must be new to keep out moisture and debris; do not reuse solenoid valve stem seals  .
    Fig 2: Internal Pump Connector O-Ring
    GC0039496Courtesy of CHRYSLER LLC
  3. Replace the pump/motor connector O-ring (1) if it is not new. Be sure the O-ring is properly seated in the mounting groove (2).
    Fig 3: ABM Assembly To HCU
    GC0039494Courtesy of CHRYSLER LLC
  4. Align components and install the ABM (1) on the HCU (2).
    Fig 4: ABM Mounting Screws - With Traction Control
    GC0039493Courtesy of CHRYSLER LLC
  5. Install the four screws (1) attaching the ABM (2) to the HCU. Tighten the mounting screws to 2 N.m (17 in. lbs.).
    Fig 5: ICU Mounting
    GC0039487Courtesy of CHRYSLER LLC
  6. Position ICU (1) above mounting grommets (2) located in body side rail and press mounting bracket into place.
    Fig 6: Left Rear And Right Rear Brake Tubes At ICU
    GC0039490Courtesy of CHRYSLER LLC
  7. Clip rear brake tubes (1, 2) to routing clip (3) on bracket below Fuse And Relay Center.
    Fig 7: Left Front And Right Front Brake Tubes At ICU
    GC0039489Courtesy of CHRYSLER LLC
  8. Clip right front brake tube (3) to routing clip on bracket below Fuse And Relay Center.
  9. Clip brake tubes to two routing clips (1) along upper radiator support.
    Fig 8: Wiring Harness Connector At ABM
    GC0039492Courtesy of CHRYSLER LLC
    CAUTION: Before installing the ABM harness connector (2) on the ABM (1), be sure the seal is properly installed in the connector.
  10. Insert ABM harness connector (2) into socket of ABM (1) and close cover, locking connector in place.
    Fig 9: LX Battery And Cables
    GC0040730Courtesy of CHRYSLER LLC
  11. Connect battery negative cable (2) to battery post. It is important that this is performed properly. Refer to STANDARD PROCEDURE .
  12. Perform Diagnostic Verification Test and clear any faults. Refer to STANDARD PROCEDURE .