Speed Control: Servo: Removal
- Disconnect the negative battery cable. See Fig 1.
- Remove 2 nuts attaching servo bracket to shock tower.
- Disconnect electrical connectors and vacuum hose.
- Remove two nuts attaching speed control cable and mounting bracket to servo.
- Pull cable away from servo to expose retaining clip and remove clip attaching cable to servo. See Fig 2.
- Remove servo mounting bracket.