Electric Fuel Pump: Operation: Notes

WARNING: This page is about a different car, the 2006 Dodge Viper. However, it is still accessible from the selected car via links, so may be relevant.

The pump draws fuel through a strainer and pushes it through the motor to the outlet. The pump contains a check valve. The valve, in the pump outlet, maintains pump pressure during engine off conditions. The fuel pump relay provides voltage to the fuel pump. The fuel pump has a maximum deadheaded pressure output of approximately 880 kPa (130 psi). The regulator adjusts fuel system pressure to approximately 379 kPa (55 psi).