Integrated Control Unit (ICU): Disassembly
Courtesy of DAIMLERCHRYSLER CORP.
| 1 - ICU |
| 2 - MOUNTING BOLT |
| 3 - MOUNTING BRACKET |
- If the mounting bracket (3) needs to be removed from the ICU, remove the single mounting bolt (2), then slide the ICU's mounting pins out of the grommets in the bracket. Remove the mounting pins from the ICU as necessary.
Courtesy of DAIMLERCHRYSLER CORP.
| 1 - MOUNTING SCREWS |
| 2 - ABM |
- If not equipped with traction control, remove the three screws (1) attaching the ABM (2) to the HCU.
Courtesy of DAIMLERCHRYSLER CORP.
| 1 - MOUNTING SCREWS |
| 2 - ABM |
- If equipped with traction control, remove the four screws (1) attaching the ABM (2) to the HCU.
Courtesy of DAIMLERCHRYSLER CORP.
| 1 - ABM |
| 2 - HCU |
| 3 - SOLENOID VALVE STEM |
- Separate the ABM (1) from the HCU (2).