When Monitored and Set Condition
- When Monitored: Ignition on.
- Set Condition: When the PCM recognizes the APP Sensor 5-Volt Supply circuit voltage is below 1.0 volt or higher than 5.2 volts.
| Possible Causes |
|---|
| APP SENSOR 5-VOLT SUPPLY CIRCUIT SHORT TO VOLTAGE |
| APP SENSOR 5-VOLT SUPPLY CIRCUIT SHORT TO GROUND |
| APP SENSOR 5-VOLT SUPPLY CIRCUIT SHORT TO SENSOR GROUND CIRCUIT(S) |
| APP SENSOR 5-VOLT SUPPLY CIRCUIT OPEN |
| TP SENSOR 5-VOLT SUPPLY CIRCUIT SHORT TO VOLTAGE |
| TP SENSOR 5-VOLT SUPPLY CIRCUIT SHORT TO GROUND |
| TP SENSOR 5-VOLT SUPPLY CIRCUIT SHORT TO SENSOR GROUND CIRCUIT(S) |
| ACCELERATOR PEDAL POSITION SENSOR |
| POWERTRAIN CONTROL MODULE |
For a complete Powertrain Control Module Circuit Diagram, (Refer to ENGINE - SCHEMATICS AND DIAGRAMS) .