When Monitored and Set Condition
- When Monitored: A constant engine speed between 900 and 1700 RPM and no other EGR or MAP sensor faults.
- Set Condition: The PCM commands the EGR valve to open. The MAP sensor value must drop by a minimum of 54 mbar (1.6 in Hg) when EGR is commanded open or a fault is set.