A/T Fluid Temperature Sensor Continuity Check
- Remove the A/T fluid temperature sensor.
- Measure the resistance between terminals 1 and 2 of the A/T fluid temperature sensor connector.
Standard value:
STANDARD VALUEA/T FLUID TEMPERATURE RESISTANCE 0°C (32°F) 16.7 - 20.5 kΩ 20°C (68°F) 7.3 - 8.9 kΩ 40°C (104°F) 3.4 - 4.2 kΩ 60°C (140°F) 1.9 - 2.2 kΩ 80°C (176°F) 1.0 - 1.2 kΩ 100°C (212°F) 0.57 - 0.69 kΩ - If the A/T fluid temperature sensor resistance is outside the specified range and the "N" range indicator light is flashing, replace the A/T fluid temperature sensor.
NOTE:
The "N" range indicator light on the combination meter flashes when the temperature reaches approximately 125°C (257°F) or greater, and then stops flashing when the temperature drops below approximately 115°C (238°F).