Assembly - ICU
- Install the CAB (Figure ) on the HCU.
- Install the 4 bolts mounting the CAB (Figure ) to the HCU. Tighten the CAB mounting bolts to a torque of 2 N.m (17 in. lbs.).
- Plug the pump/motor wiring harness into the CAB.
- Install the ICU in the vehicle and bleed the base and ABS hydraulic systems. (Refer to INSTALLATION ).