Parking Lights Fail To Flash During Alarm
- Ensure parking lights are operating properly. Repair parking lights as necessary. If parking lights are operating properly, go to next step.
- Turn ignition off. Disconnect 26-pin Remote Keyless Entry (RKE) module connector, located under center of instrument panel top cover. See Figure . Connect a 12-volt test light between RKE module connector terminal No. 2, headlight switch output circuit and ground. See Figure . Turn parking lights on. If test light illuminates, replace RKE module. See REMOTE KEYLESS ENTRY MODULE under REMOVAL & INSTALLATION. If test light does not illuminate, repair open wire. After making any repairs, perform VTSS VERIFICATION TEST under VERIFICATION TESTS.