Short Runner Valve
The Short Runner Valve (SRV) system operates under wide open throttle conditions at more than 5000 RPM to maximize engine performance. The PCM energizes SRV solenoid, allowing mechanical linkage to redirect intake airflow to 6 short runners. The PCM looks for a current spike when actuating solenoid. If spike is not present, the PCM sets a diagnostic trouble code.