Power Mirrors
Disconnect power mirror switch connector. See POWER MIRROR SWITCH under REMOVAL & INSTALLATION. Connect one end of a jumper wire to a 12-volt source and other end to specified power mirror connector terminals (mirror side). See POWER MIRROR MOTOR TEST table. Connect one end of another jumper wire to a good ground and other end to specified power mirror connector terminals (mirror side). If mirror does not operate as specified, check for open or shorted circuit between power mirror connector and power mirror. See WIRING DIAGRAMS . If circuits are okay, replace power mirror assembly. See POWER MIRROR ASSEMBLY under REMOVAL & INSTALLATION.
POWER MIRROR MOTOR TEST
| Apply 12 Volts To Terminal No. |
Ground Terminal No. |
Mirror Operation (Left) |
Mirror Operation (Right) |
| Switch Connector |
| 12 |
6 |
- |
Up |
| 13 |
1 |
Up |
- |
| 6 |
12 |
- |
Down |
| 1 |
13 |
Down |
- |
| 6 |
7 |
- |
Right |
| 1 |
8 |
Right |
- |
| 7 |
6 |
- |
Left |
| 8 |
1 |
Left |
- |
| Right Mirror Door Connector |
| 6 |
2 |
N/A |
Up |
| 2 |
6 |
N/A |
Down |
| 2 |
5 |
N/A |
Right |
| 5 |
2 |
N/A |
Left |
| 1 |
3 |
N/A |
|
Courtesy of CHRYSLER CORP.