Ground Connection Resistance Test
Connect voltmeter negative lead to negative battery post. Connect voltmeter positive lead to engine block, near negative battery cable grounding point. Crank engine and observe voltmeter reading. If voltmeter reading indicates more than 0.2 volt, repair poor ground connection or replace ground cable.