LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 1996 >> LHS >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC Systems - Automatic >> Testing - Basic Component Testing >> A/C System Charge Level Test >> Using Manifold Gauge Set

Using Manifold Gauge Set

  1. Attach clamp-on thermocouple to liquid line, as close to condenser outlet as possible. Connect gauge set to high side and low side connectors.
  2. Note discharge pressure and liquid line temperature. Use REFRIGERANT CHARGE LEVEL  table to determine if system is undercharged or overcharged.