Recliner Motor
Disconnect power seat switch. Connect jumper wires between pins No. 2 and 1, and pins No. 6 and 11. If motor does not operate, reverse jumper wires to pins No. 2 and 11, and pins No. 6 and 1. If motor does not operate, inspect wiring harness. If wiring is okay, replace motor assembly.