LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 1989 >> Conquest Automatic >> Repair and Diagnosis >> Brakes >> Traction Control >> Anti-Lock Brake System >> Bleeding Brake System >> GALANT >> Except Master Cylinder

Except Master Cylinder

  1. Loosen 2 check valve bolts approximately one turn. Check valve bolts are located on delay valve assembly. See Fig 1 . Follow brake bleeding sequence in Fig 1 . When all air is bled from system, tighten check valve bolts to 14-18 ft. lbs. (19-24 N.m).
    Fig 1: Galant Brake System Bleeding Sequence
    G100478Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  2. It is normal for brake pedal to feel heavier when bleeding rear brakes as compared to front brakes, this is due to a restriction inside the delay valve. When all air is bled from system, tighten check valve bolts to 15-18 ft. lbs. (20-24 N.m). Ensure master cylinder is filled to proper level.