Pierce Probing
NOTE:
Pierce Probing can not be performed on the following restricted circuits:
- Wires smaller than 0.35mm 2 or 22 ga
- Wires larger than 4.0 mm 2 or 12 ga
- High Voltage Cables - single cable and shielded type
- SRS - Inflatable Restraint System Circuits
- HO2S - O2 Sensor Circuits
- Ribbon Cable Circuits
- Ethernet cables (UTP, JUTP, STP) circuits
- A2B Cables / Circuits - Automotive Audio Bus (JUTP)
- Any Internally Sheathed Cables / Circuits
- Coax Cables
- Fiber Optic Circuits (POF - plastic optical fiber) and Glass Fiber
With Oscilloscope Diagnostic Kit
- Ignition / vehicle OFF
- Connect the Special Tool: CH-51450-A
Oscilloscope Diagnostic Kit & Special Tool: CH-51450-LEAD-A
Oscilloscope Basic Lead Kit into the appropriate locations:
- Blue lead = Channel A of the Oscilloscope
- Black ground connection = Ground
- Identify the section of harness to be probed.
- Open the wiring harness loom using a seem ripper to allow access to the desired circuit.
- Clip the pierce probe to the desired circuit for testing.
- Select Connect Detect on the tool
- Turn the pierce probe adjustment knob clockwise and verify Connect Detect = Green
- If Connect Detect does not = Green
Adjust the connection until Connect Detect = Green
- Go to next step: If Connect Detect = Green
- If Connect Detect does not = Green
- Collect voltage sample.
- Once testing is complete, mark the wire on either side of the probe.
- Remove the pierce probe from the wire.
- Repair the damaged insulation between the marks. Refer to: Repairing Damaged Wire Insulation
Without Oscilloscope Diagnostic Kit
- Ignition / vehicle OFF
- Identify the section of harness to be probed.
- Open the wiring harness loom using a seem ripper to allow access to the desired circuit.
- Connect the pierce probe from CH-51450-PROBE to a DMM.
- Clip the pierce probe to the desired circuit for testing and connect the other lead of the DMM to the end of the circuit.
- Test for less than 5 Ω while adjusting the knob on the pierce probe.
- If greater than 5 Ω
Adjust the connection until less than 5 Ω is measured
- Go to next step: If less than 5 Ω
- If greater than 5 Ω
- Collect voltage sample.
- Once testing is complete, mark the wire on either side of the probe.
- Remove the pierce probe from the wire.
- Repair the damaged insulation between the marks. Refer to: Repairing Damaged Wire Insulation