Removal Procedure
- Oil Filler Cap - Remove
Intake Manifold Cover (1) - Remove
Oil Filler Cap (1) - Install
Disconnect the electrical connector.
- The heated oxygen sensor in-line connector and louvered end MUST be kept clear of all grease, dirt, and other contaminants. Do NOT use cleaning solvents of any type. Do NOT drop or roughly handle the sensor.
- The heated oxygen sensor MAY be difficult to remove when the engine temperature is less than 48°C (120°F).
- Using a suitable tool, remove the heated oxygen sensor (1).
CAUTION:
Refer to Heated Oxygen and Oxygen Sensor Caution .
CAUTION:
The use of excessive force may damage the threads in the exhaust manifold / pipe.
NOTE: