Power Transfer Unit Shift Components Cleaning and Inspection
WARNING: This page is about a different variant/trim than selected.
Power Transfer Unit Shift Components Cleaning and Inspection
| Callout | Component Name |
|---|---|
| Preliminary Procedure Clean the power transfer unit shift components in cleaning solvent and air dry.
NOTE:
Minimal gear tooth wear is to be considered normal. |
|
| 1 | Power Transfer Unit Connect Spring
NOTE:
Inspect for excessive wear or damage. |
| 2 | Power Transfer Unit Shift Sleeve
NOTE:
Inspect for excessive gear tooth wear or a broke spring. |
| 3 | Power Transfer Disconnect Linear Cam
NOTE:
Inspect for excessive wear or damage. |
| 4 | Power Transfer Disconnect Rotary Cam
NOTE:
Inspect for excessive wear or damage. |
| 5 | Power Transfer Unit Actuator Worm Gear
NOTE: