Circuit/System Verification
- Ignition ON/Vehicle In Service Mode.
- Verify that the scan tool is communicating with vehicle.
- If the scan tool is not communicating with vehicle
Refer to Scan Tool Does Not Communicate with Vehicle .
- Go to next step: If the scan tool is communicating with vehicle
- If the scan tool is not communicating with vehicle
- Attempt to communicate with all devices on the object high speed GMLAN bus. Refer to Data Link References to determine how many devices should be communicating on the object high speed GMLAN bus.
- Verify two or more devices are not communicating on the object high speed GMLAN bus.
- If only one device is not communicating
Refer to Circuit/System Testing - Testing the Device Circuits.
- Go to next step: If two or more devices are not communicating
- If only one device is not communicating
- Ignition/Vehicle OFF, disconnect the scan tool from the X84 Data Link Connector. The following tests will be done at the X84 Data Link Connector.
- Ignition ON/Vehicle In Service Mode.
- Test for less than 4.5 V between each of the serial data circuit terminals listed below and ground.
- Terminal 3
- Terminal 11
- If 4.5 V or greater
Repair the short to voltage in the serial data circuit between the X84 Data Link Connector and the K56 Serial Data Gateway Module.
- Go to next step: If less than 4.5 V
- Ignition/Vehicle OFF, all access doors closed, all vehicle systems OFF, and all keys at least 3 m (9.8 ft) away from vehicle. It may take up to 10 min for all vehicle systems to power down.
- Test for greater than 100 Ω between each of the serial data circuit terminals listed below and ground.
- Terminal 3
- Terminal 11
- If 100 Ω or less
Repair the short to ground in the serial data circuit between the X84 Data Link Connector and the K56 Serial Data Gateway Module.
- Go to next step: If greater than 100 Ω
- Test for 110 - 130 Ω between the serial data circuit terminals 3 and 11.
- If less than 110 Ω
Repair the short together in the serial data circuits between the X84 Data Link Connector and the K56 Serial Data Gateway Module.
- If greater than 130 Ω
Repair the open/high resistance in the serial data circuit between the X84 Data Link Connector and the K56 Serial Data Gateway Module.
- Go to next step: If between 110 - 130 Ω
- If less than 110 Ω
- Refer to Circuit/System Testing - Serial Data Starting Point.