Circuit/System Description
The hybrid/EV battery contains 4 high voltage contactors. The high voltage contactors allow the high voltage DC batteries to be connected to the vehicle or contain the high voltage DC within the hybrid/EV battery assembly. The 4 high voltage contactors are a main positive high voltage contactor, main negative high voltage contactor, charge positive high voltage contactor, and precharge high voltage contactor. These contactors close and open in sequence and are controlled by the hybrid/EV powertrain control module 2. The hybrid/EV powertrain control module 2 supplies voltage to the control circuit for the high voltage contactors. Ground is provided through the case ground.