Home >> Chevrolet >> 2019 >> Volt Premier >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Cooling Systems >> Hybrid/EV System Heating And Cooling >> Repair Instructions >> Drive Motor Generator Control Module Cooling Outlet Hose Replacement (Underbody Line to Traction Power Inverter Module Inlet) >> Installation Procedure

Installation Procedure

  1. GM4091181Courtesy of GENERAL MOTORS COMPANY

    Drive Motor Generator Control Module Cooling Outlet Hose(1) - Install

  2. Clamp(2) - Install - Hose Clamp Replacement Guidelines - Spring Type
  3. Front Wheelhouse Liner Replacement (Left Side)Front Wheelhouse Liner Replacement (Right Side) - Install
  4. Lower the vehicle.
  5. GM4091180Courtesy of GENERAL MOTORS COMPANY

    Install a NEW seal.(2)

  6. Drive Motor Generator Control Module Cooling Outlet Hose Bolt(1) - Install and tighten[2x]9 N.m (80 lb in)
  7. GM4091179Courtesy of GENERAL MOTORS COMPANY

    Coolant Hose(1) - Install

  8. Clamp(2)Install - Hose Clamp Replacement Guidelines - Spring Type
  9. GM4091178Courtesy of GENERAL MOTORS COMPANY

    Electrical Connector(1, 2) - Connect

  10. Fill the cooling system. Drive Motor Generator Power Inverter Module Cooling System Draining and Filling