Fastener Specifications
Reusable Threaded Fastener Tightening Specifications
|
NOTE:
All fasteners listed in this table can be reused after removal. |
|
|---|---|
| Application | Specification |
| Metric (English) | |
| Battery Cable Terminal Bolt | 6 N.m (53 lb in) |
| Battery Hold Down Retainer Bolt | 22 N.m (16 lb ft) |
| Battery Hold Down Strap Bolt | 5 N.m (44 lb in) |
| Battery Negative Cable Ground Bolt @ Cylinder Head (LGX) | 22 N.m (16 lb ft) |
| Battery Negative Cable Ground Bolt @ Transmission | 22 N.m (16 lb ft) |
| Battery Negative Cable Ground Nut @ Front End Upper Tie Bar Support | 22 N.m (16 lb ft) |
| Battery Negative Cable Ground Stud (LCV) | 58 N.m (43 lb ft) |
| Battery Negative Cable Ground Stud (LGX) | 40 N.m (30 lb ft) |
| Battery Negative Cable Nut @ Battery Monitor Module | 12 N.m (106 lb in) |
| Battery Negative Post Clamp Nut | 4.5 N.m (40 lb in) |
| Battery Positive Cable Nut @ Generator | 15 N.m (11 lb ft) |
| Battery Positive Cable Nut @ Starter Solenoid (LCV) | 15 N.m (11 lb ft) |
| Battery Positive Cable Nut @ Starter Solenoid (LGX, LSY) | 12.5 N.m (111 lb in) |
| Battery Positive Junction Block Cable Nut @ Engine Wiring Harness Junction Block | 16 N.m (12 lb ft) |
| Battery Post Negative Cable Clamp Nut | 4.5 N.m (40 lb in) |
| Battery Tray Guide Bolt | 22 N.m (16 lb ft) |
| Generator Bolt | 22 N.m (16 lb ft) |
| Generator Nut | 22 N.m (16 lb ft) |
| Generator Mounting Stud (LCV) | 9 N.m (80 lb in) |
| Starter Heat Shield Bolt (LGX) | 9 N.m (80 lb in) |
| Starter Bolt (LCV) | 22 N.m (16 lb ft) |
| Starter Bolt (LGX, LSY) | 58 N.m (43 lb ft) |