GM2537269
Connector Part Information
  • Harness Type: Instrument Panel
  • OEM Connector: 2098067-2
  • Service Connector: 13576032
  • Description: 27-Way F 0.64, 2.8 Series (BU)
Terminal Part Information

Terminal Type ID Terminated Lead Diagnostic Test Probe Terminal Removal Tool Service Terminal Tray Name Core Crimp Insulation Crimp
I 13575578 J-35616-35 (VT) J-38125-553 Not Available Not Available Not Available Not Available
II 13582297 J-35616-64B (LT BU) J-38125-22 Not Available Not Available Not Available Not Available
III 13582326 J-35616-35 (VT) J-38125-553 8100-4444 Sumitomo 22 2 A
Pin Size Color Circuit Function Terminal Type ID Option
1 1 RD/BN 4240 Battery Positive Voltage III -
2 1.5 BK 2150 Ground I -
3 - - - Not Occupied - -
4 1 RD/BN 4940 Battery Positive Voltage III -
5 0.35 GY 157 Interior Lamp Control II -
6 - - - Not Occupied - -
7 0.35 BU/YE 5361 Brake Apply Sensor Signal II -
8 0.35 YE 6817 LED Backlight Dimming Control II -
9 0.35 YE/GY 44 Instrument Panel Lamp Dimmer Switch Signal II -
10 - 12 - - - Not Occupied - -
13 0.35 WH 5359 Brake Apply Sensor Control II -
14 0.35 BU/VT 1788 Traction Control Switch Signal 1 II -
15 0.35 BN/WH 781 Driver Door Lock Switch Unlock Signal II -
16 - - - Not Occupied - -
17 0.35 BU/GN 5723 Ignition Mode Switch Mode Voltage II -
18 0.5 BU 6856 Headlamp Automatic High Beam Dim Control II -
19 0.35 BN/YE 780 Driver Door Lock Switch Lock Signal II -
20 - - - Not Occupied - -
21 0.35 GN/GY 6135 Local Interconnect Network Serial Data Bus 4 II -
22 0.5 GN 5060 Low Speed GMLAN Serial Data II -
23 - 24 - - - Not Occupied - -
25 0.35 GY/WH 3272 Remote Function Actuator Control II -
26 0.35 GN/WH 111 Hazard Switch Signal II -