Installation Procedure

  1. GM4497435Courtesy of GENERAL MOTORS COMPANY

    Drive Motor Generator Control Module Cooling Outlet Hose (2) - Install

  2. Clamp (1) - Engage - Hose Clamp Replacement Guidelines - Spring Type 
  3. Position the surge tank and install the RESS surge tank bracket. Radiator Surge Tank Support Bracket Replacement (RESS) 
  4. GM4497434Courtesy of GENERAL MOTORS COMPANY

    Retainer (1) - Install

  5. Drive Motor Generator Control Module Cooling Outlet Hose (2) - Install
  6. GM4497433Courtesy of GENERAL MOTORS COMPANY

    Drive Motor Generator Control Module Cooling Outlet Hose (2) - Install

  7. Clamp (1) - Engage - Hose Clamp Replacement Guidelines - Spring Type 
  8. Fill the drive motor generator power inverter module cooling system. Drive Motor Generator Power Inverter Module Cooling System Draining and Filling 
  9. Check the cooling system for leaks.