Installation Procedure
- Install Mass Airflow Sensor(1)
- Install Mass Airflow Sensor Bolt (2) and tighten 2.5 N.m (22 lb in)
- Install Air Cleaner Upper Housing(2)
- Install Air Cleaner Upper Housing Bolt(1) and tighten 2.5 N.m (22 lb in)
- Install Air Cleaner Outlet Duct(3)@Air Cleaner Assembly(4)
- Air Cleaner Outlet Duct Clamp(2) - Tighten 2.5 N.m (22 lb in)
- Connect the electrical connector.(1)
- When the replacement is completed, use a scan tool to perform the appropriate reset functions. Control Module References
CAUTION: