Installation Procedure
- Install a NEW gasket.(1, 2)
- Install Exhaust Gas Recirculation Cooler (4)
- Install Exhaust Gas Recirculation Cooler Bolt (3)
- Install Exhaust Gas Recirculation Cooler Bolt (3) @Exhaust Gas Recirculation Cooler(1)
- Install the exhaust gas recirculation temperature sensor - position 2 (2) and tighten to 42 N.m (31 lb ft).
- Install Exhaust Gas Recirculation Cooler Bolt (2)
- Install the exhaust gas recirculation temperature sensor - position 1 (1) to the exhaust gas recirculation cooler (3) and tighten to 42 N.m (31 lb ft).
- Tighten all 6 exhaust gas recirculation cooler bolts to 10 N.m (89 lb in)
- Connect Thermostat Bypass Hose (2) -
- Tighten Thermostat Bypass Hose Clamp (1) - Tighten
- Connect Heater Inlet Hose (2) @Exhaust Gas Recirculation Cooler (1)
- Connect Exhaust Gas Recirculation Cooler Water Bypass Outlet Hose (4) @Exhaust Gas Recirculation Cooler (1)
- Clamp (3) - Tighten
- Install Three-Way Catalytic Converter Replacement
- Fill the cooling system. Cooling System Draining and Filling