Circuit/System Testing
NOTE:
Circuit/System Verification must be performed before proceeding with Circuit/System Testing.
- Ignition OFF, disconnect the harness connector at the ignition switch.
- Ignition ON, verify that a test lamp illuminates between the B+ circuit terminal 2 and ground.
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the power mode circuit fuse is open, test the signal circuit terminal 4 for a short to ground.
- Verify the scan tool Key In Ignition Status parameter is Key Out.
- If not the specified value, test the signal circuit terminal 4 for a short to voltage. If the circuit tests normal, replace the BCM.
- Install a 3A fused jumper wire between the signal circuit terminal 4 and the B+ circuit terminal 2. Verify the scan tool Key in Ignition Status parameter is Key In.
- If not the specified value, test the signal circuit for an open/high resistance. If the circuit tests normal, replace the BCM.
- If all circuits test normal, test or replace the ignition switch.