Component Testing
Lumbar Switch
- Ignition OFF, disconnect the harness connector at the lumbar switch.
- Test for infinite resistance between the B+ terminal G and each motor control terminal with the switch in the open position.
- If not the specified value, replace the lumbar switch.
- Test for less than 2 ohm between the B+ terminal G and each motor control terminal with the switch in the closed position.
- If greater than the specified range, replace the lumbar switch.
- Test for less than 2 ohm between the ground terminal E and each motor control terminal with the switch in the open position
- If greater than the specified range, replace the lumbar switch.