Circuit/System Testing
- Ignition OFF, disconnect the WPR HI relay.
- Connect a test lamp between the control circuit terminal 86 and B+.
- Ignition ON, command the high speed wipers ON and OFF using the wiper switch. The test lamp should turn ON and OFF when changing between the commanded states.
- If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the BCM.
- If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM.