Circuit/System Testing
- Ignition OFF and all vehicle systems OFF, disconnect the X1 harness connector at the P17 Info Display Module.
- Ignition ON.
- Verify a test lamp does not illuminate between the signal circuit terminal 8 and ground.
- If the test lamp illuminates
- Ignition OFF, disconnect the harness connector at the A26 HVAC Controls. Ignition ON.
- Test for less than 1 V between the signal circuit and ground.
- If 1 V or greater, repair the short to voltage on the circuit.
- If less than 1 V, replace the A26 HVAC Controls.
- If the test lamp does not illuminate
- Test for greater than 11 V between the signal circuit terminal 8 and ground while pressing the eject switch.
- Ignition OFF, disconnect the harness connector at the A26 HVAC Controls.
- Test for infinite resistance between the signal circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- Test for less than 2 Ω in the signal circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, replace the A26 HVAC Controls.
- Test or replace the P17 Info Display module.