Component Testing
- Ignition/Vehicle - Off
- Disconnect the electrical connector: Q6 Camshaft Position Actuator Solenoid Valve
- Test for 6.7 to 7.7 ohms between the test points:Terminal 1 & Terminal 2
- If not between 6.7 and 7.7 ohms
Replace the component: Q6 Camshaft Position Actuator Solenoid Valve.
- Go to next step: If between 6.7 and 7.7 ohms
- If not between 6.7 and 7.7 ohms
- Test for infinite resistance between the test points:Terminal 1 & Ground
- Test for infinite resistance between the test points:Terminal 2 & Ground
- If less than infinite resistance
Replace the component:Q6 Camshaft Position Actuator Solenoid Valve
- Go to next step: If infinite resistance
- If less than infinite resistance
- All OK.