Typical Scan Tool Data
Internal Mode Switch A/B/C/P
| Circuit | Normal Range | Short to Ground | Open | Short to Voltage |
|---|---|---|---|---|
| Operating Conditions: Vehicle ON, range selector in Park | ||||
| Internal Mode Switch A | 1.62 V - 2.49 V | Less than 0.66 V | Greater than 2.49 V | Greater than 2.49 V |
| Internal Mode Switch B | 0.66 V - 1.02 V | Less than 0.66 V | Greater than 2.49 V | Greater than 2.49 V |
| Internal Mode Switch C | 0.66 V - 1.02 V | Less than 0.66 V | Greater than 2.49 V | Greater than 2.49 V |
| Internal Mode Switch P | 1.62 V - 2.49 V | Less than 0.66 V | Greater than 2.49 V | Greater than 2.49 V |
| Internal Mode Switch S | 1.62 V - 2.49 V | Less than 0.66 V | Greater than 2.49 V | Greater than 2.49 V |
| Valid High = Switch open = 1.62 V - 2.49 V Valid Low = Switch Closed = 0.66 V - 1.02 V |
||||