Internal Mode Switch A/B/C/P

Circuit Normal Range Short to Ground Open Short to Voltage
Operating Conditions:  Vehicle ON, range selector in Park
Internal Mode Switch A 1.62 V - 2.49 V Less than 0.66 V Greater than 2.49 V Greater than 2.49 V
Internal Mode Switch B 0.66 V - 1.02 V Less than 0.66 V Greater than 2.49 V Greater than 2.49 V
Internal Mode Switch C 0.66 V - 1.02 V Less than 0.66 V Greater than 2.49 V Greater than 2.49 V
Internal Mode Switch P 1.62 V - 2.49 V Less than 0.66 V Greater than 2.49 V Greater than 2.49 V
Internal Mode Switch S 1.62 V - 2.49 V Less than 0.66 V Greater than 2.49 V Greater than 2.49 V
Valid High = Switch open = 1.62 V - 2.49 V
Valid Low = Switch Closed = 0.66 V - 1.02 V