Removal Procedure

WARNING:

Before conducting any repair to this high voltage cooling system, it is necessary to determine/verify whether no high-voltage system faults exist. If high-voltage faults exist, follow published DTC diagnostics/repair procedures prior to performing any cooling system repairs. Failure to correct High Voltage Faults before working on the high voltage cooling system could result in personal injury or death.

  1. Turn vehicle power OFF and remove all keyless entry transmitters from the vehicle and secure in a place outside the vehicle.
  2. Drain the drive motor generator power inverter module cooling system. Refer to Drive Motor Generator Power Inverter Module Cooling System Draining and Filling 
  3. Fig 1: Drive Motor Generator Control Module Cooling Outlet Hose
    GM4497433Courtesy of GENERAL MOTORS COMPANY
  4. Disengage Clamp (1). Refer to Hose Clamp Replacement Guidelines - Spring Type 
  5. Remove Drive Motor Generator Control Module Cooling Outlet Hose (2)
  6. Fig 2: Drive Motor Generator Control Module Cooling Outlet Hose And Retainer
    GM4497434Courtesy of GENERAL MOTORS COMPANY
  7. Remove Retainer (1)
  8. Remove Drive Motor Generator Control Module Cooling Outlet Hose (2)
  9. Remove the RESS surge tank bracket and reposition the surge tank. Refer to Radiator Surge Tank Support Bracket Replacement (RESS) 
  10. Fig 3: Drive Motor Generator Control Module Cooling Outlet Hose And Clamp
    GM4497435Courtesy of GENERAL MOTORS COMPANY
  11. Disengage Clamp (1). Refer to Hose Clamp Replacement Guidelines - Spring Type 