Circuit/System Verification
- Vehicle in Service Mode. Depress the receptacle switch with a small screw driver. With a scan command the DC Charge Port Lock between UNLOCK and LOCK.
- Observe the scan tool DC Charge Port Lock Actuator Position Sensor parameter. The reading should change between 0.15 - 1.75 V (UNLOCKED) and 3.75 - 4.85 V (LOCKED).
- The reading are not within the specified ranges
Refer to Circuit/System Testing.
- The reading are within the specified ranges
- The reading are not within the specified ranges
- Verify that DTC P302B, P302C, or P302D is not set.
- If any of the DTCs are set
Refer to Circuit/System Testing.
- If none of the DTCs are set
- If any of the DTCs are set
- All OK.
NOTE:
If the receptacle switch is not fully depressed the reading will remain below 2 V.