Hybrid Powertrain Control Module 2 Scan Tool Information

Charge History Scan Tool Data Parameters

Parameter Expected Value Definition
Operating Conditions:  The Charge History parameters capture the conditions present during the last five alternating current (AC) charge events. A charge event is recorded whenever the charge coupler is fully mated to the charge receptacle. History 1 is the most recent charge event. The Charge History parameters are cleared only during an HPCM2 replacement and/or programming event.
Charge History (1 thru 5) - 110V AC Input Varies This parameter displays if the 110V charge cord was active during this charge event.
Charge History (1 thru 5) - 240V AC Input Varies This parameter displays if the 240V charge cord was active during this charge event.
Charge History (1 thru 5) - Autostart Inhibit Varies This parameter displays if the charge event was interrupted because of an engine start. An engine start could be commanded via remote start, key crank, cold battery, etc.
Charge History (1 thru 5) - Battery Charger Temperature Too High No This parameter displays if the charge event was interrupted because the Battery Charger internal temperature exceeded a set value. Refer to DTC P1EF3-P1EF5.
Charge History (1 thru 5) - Charging Cord Error No This parameter displays if the vehicle battery charger is requesting utility power but AC input voltage is not present. Refer to DTC P1EE6.
Charge History (1 thru 5) - Contactor Open No This parameter displays if the charging related contactor(s) were commanded open, interrupting the charge event.
Charge History (1 thru 5) - Full Charge Varies This parameter displays if the high voltage battery was completely charged during this charge event.
Charge History (1 thru 5) - High Severity Fault No This parameter displays if high voltage battery DTCs such as cell overvoltage had set, inhibiting the charge event.
Charge History (1 thru 5) - Hybrid/EV Battery Pack Protection No This parameter displays if high voltage battery DTCs had set, inhibiting the charge event.
Charge History (1 thru 5) - Hybrid/EV Battery Pack Temperature Too Low No This parameter displays if the charge event was interrupted because the high voltage battery temperature was too low to allow charging.
Charge History (1 thru 5) - Low Severity Fault No This parameter displays if high voltage battery DTCs had set, interrupting the charge event.
Charge History (1 thru 5) - Low Voltage - Battery Voltage Low Before Charge No This parameter displays if the 12 V accessory battery voltage was too low prior to the charging event being enabled.
Charge History (1 thru 5) - Low Voltage - Battery Voltage Low During Charge No This parameter displays if the 12V accessory battery voltage was too low during the charge event.
Charge History (1 thru 5) - Maximum Cell Voltage No This parameter displays if the maximum voltage for one of the high voltage battery cells was exceeded, interrupting the charge event.
Charge History (1 thru 5) - Maximum Charge Time Exceeded No This parameter displays if the maximum charge time was exceeded during this charge event. Maximum charge time varies by vehicle model with 40 hours being the shortest maximum allowed charge time.
Charge History (1 thru 5) - Medium Severity Fault No This parameter displays if high voltage battery DTCs had set, interrupting the charge event.
Charge History (1 thru 5) - Multiple Plug-In Events Within 30 Seconds No This parameter displays if that several charge cord connections/disconnections were observed at the charger receptacle in a 30 second time frame.
Charge History (1 thru 5) - Multiple Plug-In Events Within 5 Minutes No This parameter displays if that several charge cord connections/disconnections were observed at the charger receptacle in a 5 minute time frame.
Charge History (1 thru 5) - Time of Day Inhibit Varies This parameter displays if programmable charging (time of day/rate based) had delayed charging at some point during this event.
Charge History (1 thru 5) - Unplugged at Vehicle Varies This parameter displays if the charge event was interrupted because the charge cord was disconnected at the vehicle charge receptacle.
Charge History (1 thru 5) - Unplugged at Wall Varies This parameter displays if the charge event was interrupted when AC voltage was lost to the charge cord. Most likely this occurred by either the charge cord plug being removed from the household receptacle or a household utility circuit breaker tripping open.
Charge History (1 thru 5) - Utility Company Inhibit Varies This parameter displays if smart charging had delayed charging at some point during this charge event due to a utility company commanded transmitted via Onstar.
Charge History (1 thru 5) - Vehicle Conditions Not Correct Yes This parameter displays if the required vehicle conditions to allow charging such as gear selector in Park, valid charger pilot signal have been met.
DC Charge History Scan Tool Data Parameters (w/CBT)

Parameter Expected Value Definition
Operating Conditions:  The DC Charge History parameters capture the conditions present during the last five fast charge events. A fast charge event is recorded whenever the charge coupler is fully mated to the charge receptacle. History 1 is the most recent charge event. The DC Charge History parameters are cleared only during an HPCM2 replacement and/or programming event.
DC Charge History (1 thru 5) - Active Cooling and Charging Enabled Varies This parameter displays if active cooling was active during this charge event. The electric A/C compressor will be turned ON and the coolant control valve will be set to the chiller position allowing the air conditioning refrigerant to cool the hybrid/EV battery coolant.
DC Charge History (1 thru 5) - Active Cooling Enabled Varies This parameter displays if active cooling was active. The electric A/C compressor will be turned ON and the coolant control valve will be set to the chiller position allowing the air conditioning refrigerant to cool the hybrid/EV battery coolant.
DC Charge History (1 thru 5) - Active Heating and Charging Enabled Varies This parameter displays if active heating was active during this charge event. The electric battery heater will be turned ON allowing the heated coolant to warm the hybrid/EV battery.
DC Charge History (1 thru 5) - Bulk Charge Complete Varies This parameter displays if the high voltage battery was almost completely charged.
DC Charge History (1 thru 5) - Charge Contactors Allowed to Close Varies This parameter displays if the DC Charge Contactors closed.
DC Charge History (1 thru 5) - Charge High Voltage Output Active Varies This parameter displays if the DC charge contactors are closed.
DC Charge History (1 thru 5) - Charge Receptacle Overtemperature No This parameter displays if the system has commanded the DC Charge contactors open to protect the charge receptacle from overheating.
DC Charge History (1 thru 5) - Charge Station Pilot Duty Cycle Not 5% No This parameter displays if a valid Pilot signal was not received.
DC Charge History (1 thru 5) - Charge System Integrity Not Verified No This parameter displays if the DC Charge system integrity was not verified.
DC Charge History (1 thru 5) - Charge System Integrity Verified Yes This parameter displays if the DC Charge system integrity was verified.
DC Charge History (1 thru 5) - Charger Functions Available Yes This parameter displays if the DC Charger functions are available.
DC Charge History (1 thru 5) - Charger Functions Unavailable No This parameter displays if the DC Charger functions are not available.
DC Charge History (1 thru 5) - Charging Conditions Correct Varies This parameter displays if the required vehicle conditions to allow charging such as gear selector in Park, valid charger pilot signal have been met.
DC Charge History (1 thru 5) - Charging Conditions Not Correct Varies This parameter displays if the required vehicle conditions to allow charging such as gear selector in Park, valid charger pilot signal have not been met.
DC Charge History (1 thru 5) - Charging Enabled Varies This parameter displays if DC charging was enabled.
DC Charge History (1 thru 5) - Charging Stopped By Charge Station Varies This parameter displays if DC charging was interrupted by the off-vehicle charge station.
DC Charge History (1 thru 5) - Charging Stopped by Cordset Varies This parameter displays if DC charging was interrupted by the Cordset.
DC Charge History (1 thru 5) - Contactor Open Request Varies This parameter displays if the charging related contactor(s) were commanded open, interrupting the charge event.
DC Charge History (1 thru 5) - Cordset Correct for Charging Yes This parameter displays if the correct cordset was connected to the vehicle.
DC Charge History (1 thru 5) - DC Charge Current Reduced for Battery Protection No This parameter displays if the DC charge level was reduced to protect the Hybrid/EV battery during certain conditions such as the temperature too high.
DC Charge History (1 thru 5) - DC Enabled Since Plug-In Varies This parameter displays if DC charging was enabled since the cordset was plugged in.
DC Charge History (1 thru 5) - DC Not Provided No This parameter displays if DC voltage was not provided by the off-vehicle charge station.
DC Charge History (1 thru 5) - Full Charge Varies This parameter displays if the high voltage battery was completely charged.
DC Charge History (1 thru 5) - High Severity Fault No This parameter displays if high voltage battery DTCs such as cell overvoltage had set, inhibiting the charge event.
DC Charge History (1 thru 5) - Hybrid/EV Battery Pack Protection No This parameter displays if the DC charge was disabled to protect the Hybrid/EV battery during certain conditions such as the temperature too high.
DC Charge History (1 thru 5) - Hybrid/EV Battery Pack Temperature Too High Varies This parameter displays if the charge event was interrupted because the high voltage battery temperature was too high to allow charging.
DC Charge History (1 thru 5) - Hybrid/EV Battery Pack Temperature Too Low Varies This parameter displays if the charge event was interrupted because the high voltage battery temperature was too low to allow charging.
DC Charge History (1 thru 5) - Insufficient Current from Charge Station No This parameter displays if the off-vehicle charge station did not provide sufficient current to allow charging.
DC Charge History (1 thru 5) - Lost Communication with DC Charging Control Module No This parameter displays if the hybrid powertrain control module 2 lost communication with the T24 Battery Charger module.
DC Charge History (1 thru 5) - Low Severity Fault No This parameter displays if high voltage battery DTCs had set, interrupting the charge event.
DC Charge History (1 thru 5) - Low Voltage Battery Low Before Charging No This parameter displays if the 12 V accessory battery voltage was too low prior to the charging event being enabled.
DC Charge History (1 thru 5) - Low Voltage Battery Low During Charging No This parameter displays if the 12 V accessory battery voltage was too low during the charge event.
DC Charge History (1 thru 5) - Maximum Cell Voltage No This parameter displays if the maximum voltage for one of the high voltage battery cells was exceeded, interrupting the charge event.
DC Charge History (1 thru 5) - Medium Severity Fault No This parameter displays if high voltage battery DTCs had set, interrupting the charge event.
DC Charge History (1 thru 5) - Multiple Plug-In Events Within 30 Seconds No This parameter displays if that several charge cord connections/disconnections were observed at the charger receptacle in a 30 second time frame.
DC Charge History (1 thru 5) - Multiple Plug-In Events Within 5 Minutes Varies This parameter displays if that several charge cord connections/disconnections were observed at the charger receptacle in a 5 minute time frame.
DC Charge History (1 thru 5) - Precharge Failure No This parameter displays if a precharge failure occurred, interrupting the charge event. Precharge occurs in the milliseconds prior to closing both the main bus contactors. By routing the high voltage through a resistor, precharge prevents voltage spikes from occurring whenever high voltage is enabled.
DC Charge History (1 thru 5) - Propulsion System Active Varies This parameter displays if DC charging was inhibited because the propulsion system was active.
DC Charge History (1 thru 5) - Run/Crank Active Varies This parameter displays if the ignition power mode was in Run/Crank.
DC Charge History (1 thru 5) - Vehicle Conditions Correct For Charging Yes This parameter displays if the required vehicle conditions to allow charging such as gear selector in Park, valid charger pilot signal have been met.
DC Charge History (1 thru 5) - Vehicle Requested Current Below Charge Station Limits Varies This parameter displays if the off-vehicle charge station was unable to provide charge current as low as the vehicle requested.
Hybrid Powertrain Control Module 2 Configuration/Reset Functions

Output Control Description
DC Charging Disable Reset This reset function is used to reset a DC Charge Disabled condition.
EV Range Reset This reset function is used to reset the learned EV Range displayed to the operator of the vehicle.
Hybrid/EV Battery Contactor Open Reasons Reset This reset function is used to clear the contactor open reasons history.
Hybrid/EV Battery Pack Capacity Learn This reset function is used to learn the hybrid/EV battery pack capacity whenever the HPCM2, the Hybrid/EV Battery pack or individual hybrid/EV battery sections are replaced. Refer to the Hybrid/EV Battery Pack Capacity Learn procedure in Hybrid/EV Energy Storage.
Hybrid/EV Battery Pack Charging Adaptive Learn Reset This reset function is used to reset the learned adaptive charging limits.
Hybrid/EV Battery Pack Coolant Control Solenoid Valve Learn This reset function is used to learn the end-stop positions of the coolant valve.
Hybrid/EV Battery Pack Data Reset This reset function is used to reset certain engineering data parameters.
Hybrid Powertrain Control Module 2 Scan Tool Data Parameters

Parameter System State Expected Value Description
Operating Conditions:  Vehicle in Run
14V Power Module Power Available From Hybrid/EV Battery Pack - Varies This parameter displays the amount of electrical power in kW the Hybrid/EV battery pack can supply to the 14V Power Module.
A/C Compressor Power Limit - No This parameter displays if the electric power available to the Electric A/C compressor motor is at its limit.
A/C Compressor Speed - Varies This parameter displays the actual speed of the electric A/C compressor motor shaft.
A/C High Side Pressure Sensor Compressor OFF Equal to low side This parameter displays the pressure of the A/C system high side pressure sensor.
Compressor ON Higher than low side
A/C Low Side Pressure Sensor Compressor OFF Equal to high side This parameter displays the pressure of the A/C system low side pressure sensor.
Compressor ON Lower than high side
A/C Low Side Pressure Sensor - Varies This parameter displays the voltage of the A/C system low side pressure sensor.
Airbag Deployed - No This parameter displays if the contactors are commanded open because an air bag has deployed.
Ambient Air Temperature - Varies This parameter displays the temperature of the air surrounding the vehicle.
Average Hybrid/EV Battery Pack Temperature - Varies This parameter displays the average temperature for all of the Hybrid/EV battery pack module sensors.
Battery Charger High Output - Varies This parameter displays the current in amps supplied by the Battery Charger Control Module to the high voltage battery.
Battery Charger High Output - Varies This parameter displays the power in kW supplied by the Battery Charger Control Module to the Hybrid/EV battery pack.
Battery Charger High Output - Varies This parameter displays the voltage supplied by the Battery Charger Control Module to the high voltage battery.
Battery Charger High Voltage Energy Output During Last Charge - Varies This parameter displays the energy (kWh) the battery charger has delivered into the high voltage Hybrid/EV battery pack during the last charge event.
Battery Charger High Voltage Power Output Available - Varies This parameter displays the maximum battery charger power output in kW available for Hybrid/EV battery pack charging.
Battery Charger Input - Varies This parameter displays the current in amps monitored by the Battery Charger Control Module on the charge cord.
Battery Charger Input - Varies This parameter displays the voltage monitored by the Battery Charger Control Module on the charge cord.
Battery Charger Input 120V AC - Varies This parameter displays the battery charging system is connected to 120V AC.
Battery Charger Input 240V AC - Varies This parameter displays the battery charging system is connected to 240V AC.
Battery Charger Low Output - Varies This parameter displays the current in amps supplied by the Battery Charger Control Module to the 12V accessory battery.
Battery Charger Low Output - Varies This parameter displays the power in kW supplied by the Battery Charger Control Module to the 12V accessory battery.
Battery Charger Low Output - Varies This parameter displays the voltage supplied by the Battery Charger Control Module to the 12V accessory battery.
Battery Charger Power Input Available - Varies This parameter displays the maximum power in kW available at the battery charger plug receptacle coming from the wall outlet/utility supply.
Battery Charger Temperature - Varies This parameter displays the temperature of the Battery Charger Control Module internal temperature sensor.
Battery Charger Total Power Output Available - Varies This parameter displays the maximum battery charger power output in watts available for low voltage battery and hybrid battery pack charging
Battery Charging System - OK This parameter displays if the components that make up the charge system are allowing charging.
Battery Charging System Indicator Status - Varies This parameter displays the status of the charging system indicator (LEDs/Bulbs/Icons) visible to the operator of the vehicle.
Battery Charging System Isolation Test Status - Passed Vehicles equipped with high voltage storage and propulsion capability are designed with both the positive and negative high voltage circuits isolated from the vehicle chassis. This parameter displays the results obtained when the Hybrid/EV battery pack last performed an isolation diagnostic test on the battery charging system.
Battery Charging System Negative Contactor Command In Charge Mode Closed This parameter displays the Hybrid Powertrain Control Module 2 Commanded state of the contactor (relay) on (-) side of the battery charging system.
Not in Charge Mode Open
Battery Charging System Operating Conditions - OK This parameter displays if the battery charging system operating conditions are allowing charging.
Battery Charging System Positive Contactor Command In Charge Mode Closed This parameter displays the Hybrid Powertrain Control Module 2 Commanded state of the contactor (relay) on (+) side of the battery charging system.
Not in Charge Mode Open
Battery Charging System Receptacle Switch Charge Cord Installed Active This parameter displays the state of the switch at the receptacle where the charge cord plugs in.
Charge cord unplugged Inactive
Charge Port Door - Varies This parameter displays the state of the switch at the door where the charge cord plugs in.
Cooling Fan Motor Command - Varies This parameter displays the commanded air flow in percent of the radiator coolant fan.
Crash Event Detected - No This parameter displays if the contactors are commanded open due to a vehicle crash event being detected.
DC Charge Port Current - Varies This parameter displays the amount of current flowing though the charge receptacle DC terminals.
DC Charge Port Lock Actuator Position Sensor - - This parameter displays the voltage of the B281 lock actuator position sensor.
DC Charge Port Lock Position Sensor - - This parameter displays the voltage of the B281 lock position sensor.
DC Charge Port Temperature - - This parameter displays the temperature of the X98 Hybrid/EV Battery Charger Receptacle internal temperature sensor.
DC Negative Supply Isolation Voltage - - This parameter indicates the T24 Battery Charger - DC isolation sensor circuit voltage for the DC charge negative (-) HV bus. The negative and positive isolation voltage parameters will shift in respect to each other if HV isolation to chassis decreases.
DC Positive Supply Isolation Voltage - - This parameter indicates the T24 Battery Charger - DC isolation sensor circuit voltage for the DC charge positive (+) HV bus. The negative and positive isolation voltage parameters will shift in respect to each other if HV isolation to chassis decreases.
Discharging - No This parameter displays if the system is inhibiting contactor closure because the high voltage system is currently in the process of discharging the capacitors on the high voltage bus. Discharging usually occurs immediately following opening of the high voltage contactors.
Distance Since DTC Cleared - Varies This parameter displays the distance in miles or kilometers since OBD diagnostic trouble codes (DTCs) have been cleared using the service tool.
Distance With MIL On - Varies This parameter displays the accumulated distance in miles or kilometers driven with the malfunction indicator lamp (MIL) on.
High Voltage Interlock Circuit Fault - No This parameter displays if the contactors are commanded open because the high voltage interlock circuit is detected open or faulted.
High Voltage System Interlock Circuit HV Enabled Energized The high voltage interlock circuit routes through several components and connectors to determine if access to high voltage components is being attempted. This parameter displays if the high voltage interlock circuit is currently monitoring for high voltage system integrity.
HV Not Enabled De-Energized
High Voltage System Interlock Circuit Status HV Enabled Pass The high voltage interlock circuit routes through several components and connectors to determine if access to high voltage components is being attempted. This parameter displays the results of the control modules diagnostic test of the high voltage interlock circuit.
HV Not Enabled Unknown
High Voltage System Isolation Test Status HV Enabled Not Running Vehicles equipped with high voltage storage and propulsion capability are designed with both the positive and negative high voltage circuits isolated from the vehicle chassis. This parameter displays the status of the Hybrid/EV battery pack isolation diagnostic test. This test may run at accessory wake up or immediately following key-off. The status will clear whenever DTCs are cleared.
HV Not Enabled Running/Complete
Hybrid/EV Battery DC Charging Negative Contactor Command - Varies This parameter displays the T24 Battery Charger - DC Commanded state of the contactor (relay) on (-) side of the DC battery charging system.
Hybrid/EV Battery DC Charging Positive Contactor Command - Varies This parameter displays the T24 Battery Charger - DC Commanded state of the contactor (relay) on (+) side of the DC battery charging system.
Hybrid/EV Battery Pack Charging Limit - Varies This parameter displays the maximum charge power limit in watts of the Hybrid/EV battery pack based on current conditions such as temperature and state of charge.
Hybrid/EV Battery Pack Charging Request - Varies This parameter displays the request to charge the Hybrid/EV Battery pack.
Hybrid/EV Battery Pack Coolant Control Solenoid Valve Command - Varies This parameter displays the commanded position for the solenoid valve that controls the coolant flow through the Hybrid/EV battery pack cooling system. This position determines the percentage of coolant allowed to flow through the refrigerant/coolant exchanger (chiller).
Hybrid/EV Battery Pack Coolant Control Solenoid Valve Feedback - Varies This parameter displays the actual position for the solenoid valve that controls the coolant flow through the Hybrid/EV battery pack cooling system. This position determines the percentage of coolant allowed to flow through the refrigerant/coolant exchanger (chiller).
Hybrid/EV Battery Pack Coolant Control Solenoid Valve Learn Status - Complete This parameter displays the status of the learn test for the solenoid valve that controls the coolant flow through the Hybrid/EV battery pack.
Hybrid/EV Battery Pack Coolant Control Valve Position - Varies This parameter displays the percentage of coolant flow allowed to both flow through and bypass the refrigerant/coolant exchanger (chiller).
Hybrid/EV Battery Pack Coolant Level Switch - Varies This parameter displays the voltage signal from the coolant level switch contained in the Hybrid/EV battery pack coolant surge tank.
Hybrid/EV Battery Pack Coolant Pump Command - Varies This parameter displays the commanded percentage coolant flow for the Hybrid/EV battery pack coolant pump.
Hybrid/EV Battery Pack Coolant Pump Feedback - 45-55% This parameter displays the internal diagnostic status of the Hybrid/EV battery pack coolant pump. A duty cycle of 45 to 55% indicates no internal pump faults detected.
Hybrid/EV Battery Pack Coolant Pump Speed - Varies This parameter displays the actual speed of the Hybrid/EV battery pack coolant pump motor shaft.
Hybrid/EV Battery Pack Coolant Temperature Sensor 1 - Varies Two sensors monitor the temperature of coolant circulating through the Hybrid/EV battery pack. This parameter displays Sensor 1 which monitors temperature of the coolant entering the battery pack.
Hybrid/EV Battery Pack Coolant Temperature Sensor 2 - Varies Two sensors monitor the temperature of coolant circulating through the Hybrid/EV battery pack. This parameter displays Sensor 2 which monitors temperature of the coolant exiting the battery pack.
Hybrid/EV Battery Pack Current - Varies This parameter displays the amount of current in amps flowing in or out of the Hybrid/EV battery pack.
Hybrid/EV Battery Pack Heater Power Command - Varies This parameter displays the electric power in percent commanded by the Hybrid Powertrain Control Module 2 to the Hybrid/EV battery pack coolant heater in order to warm the battery pack.
Hybrid/EV Battery Pack Heater Power Command - Varies This parameter displays the electric power in kW commanded by the Hybrid Powertrain Control Module 2 to the Hybrid/EV battery pack coolant heater in order to warm the battery pack.
Hybrid/EV Battery Pack Heater Power Limited - No This parameter displays if the electric power available to the Hybrid/EV battery pack coolant heater is at its limit.
Hybrid/EV Battery Pack Heater Power Request - Varies This parameter displays the electric power in kW requested by the hybrid powertrain control module 2 to the Hybrid/EV battery pack coolant heater in order to warm the battery pack.
Hybrid/EV Battery Pack Isolation Test Status - Passed Vehicles equipped with high voltage storage and propulsion capability are designed with both the positive and negative high voltage circuits isolated from the vehicle chassis. This parameter displays the results obtained when the Hybrid/EV battery pack last performed its internal isolation diagnostic test. This test may run at accessory wake up or immediately following key-off. The status will be cleared whenever DTCs are cleared.
Hybrid/EV Battery Pack Maximum Voltage - Varies This parameter displays the total Hybrid/EV battery pack maximum voltage measured during the current ignition cycle.
Hybrid/EV Battery Pack Minimum State of Charge Limit - Varies This parameter displays the minimum permissible Hybrid/EV battery pack state of charge in percent. The Hybrid/EV system will not discharge the battery pack below this limit.
Hybrid/EV Battery Pack Minimum Voltage - Varies This parameter displays the total Hybrid/EV battery pack minimum voltage measured during the current ignition cycle.
Hybrid/EV Battery Pack Multifunction Contactor Command - Varies This parameter displays the Hybrid Powertrain Control Module 2 Commanded state of the contactor (relay) that supplies (+) power to the precharge resistor, the battery heater and the Charging contactor within the Hybrid/EV Battery pack.
Hybrid/EV Battery Pack Negative Contactor Command HV Enabled Closed This parameter displays the Hybrid Powertrain Control Module 2 Commanded state of the contactor (relay) on the (-) side of the Hybrid/EV Battery pack.
HV Not Enabled Open
Hybrid/EV Battery Pack Positive Contactor Command HV Enabled Closed This parameter displays the Hybrid Powertrain Control Module 2 Commanded state of the contactor (relay) on the (+) side of the Hybrid/EV Battery pack.
HV Not Enabled Open
Hybrid/EV Battery Pack Precharge Transistor Command HV Enable Initiated Closed This parameter displays the Hybrid Powertrain Control Module 2 Commanded state of the operation of the Hybrid/EV Battery pack precharge transistor. Precharge occurs in the milliseconds prior to closing the main (+) bus contactor. By routing the high voltage through a resistor, precharge prevents voltage spikes from occurring whenever high voltage is enabled.
HV Fully Enabled or HV Not Enabled Open
Hybrid/EV Battery Pack Resistance - Varies This parameter displays the Hybrid/EV battery pack resistance value in ohms.
Hybrid/EV Battery Pack State of Charge - Varies This parameter displays the percentage available capacity remaining in a Hybrid/EV battery pack.
Hybrid/EV Battery Pack State of Charge Gauge - Varies This parameter displays the percentage Hybrid/EV battery pack state of charge as indicated to the operator of the vehicle.
Hybrid/EV Battery Pack Voltage - Varies This parameter displays the electrical potential of the Hybrid/EV battery pack as currently monitored.
Hybrid/EV Battery System Precharge Current Too High - No Precharge occurs in the milliseconds prior to closing the main (+) bus contactor. By routing the high voltage through a resistor, precharge prevents voltage spikes from occurring whenever high voltage is enabled. This parameter displays if the contactors are commanded open because of excessive Precharge current.
Hybrid/EV Battery System Precharge Time Short - No Precharge occurs in the milliseconds prior to closing the main (+) bus contactor. By routing high voltage through a resistor, precharge prevents voltage spikes from occurring whenever high voltage is enabled. The time required to precharge is based upon the system voltage and capacitance. This parameter displays if the contactors are commanded open because the time required to precharge was too fast.
Hybrid/EV Battery System Precharge Time Too Long - No Precharge occurs in the milliseconds prior to closing the main (+) bus contactor. By routing the high voltage through a resistor, precharge prevents voltage spikes from occurring whenever high voltage is enabled. The time required to precharge is based upon the system voltage and capacitance. This parameter displays if the contactors are commanded open because the time required to precharge was too slow.
Hybrid/EV Battery Temperature Sensor with Maximum Value - Varies The Hybrid/EV battery pack contains many individual battery cells or modules. This parameter displays the index-number of the battery module that is reporting the maximum temperature value.
Hybrid/EV Battery Temperature Sensor with Minimum Value - Varies The Hybrid/EV battery pack contains many individual battery cells or modules. This parameter displays the index-number of the battery module that is reporting the minimum temperature value.
Hybrid/EV Battery Thermal Conditioning Request - Varies This parameter displays the desired thermal support for the Hybrid/EV battery pack. Active Heating and Active Cooling states indicate that high voltage electrical energy is being expended to meet the desired thermal conditioning.
Hybrid/EV Battery Thermal Conditioning Status - Varies This parameter displays the actual thermal support for the Hybrid/EV battery pack. Active Heating and Active Cooling states indicate that high voltage electrical energy is being expended to meet the desired thermal conditioning.
Hybrid/EV Battery Voltage Sensor with Maximum Value - Varies The Hybrid/EV battery pack contains many individual battery cells or modules. This parameter displays the index-number of the battery module voltage sensor that is reporting the highest voltage.
Hybrid/EV Battery Voltage Sensor with Minimum Value - Varies The Hybrid/EV battery pack contains many individual battery cells or modules. This parameter displays the index-number of the battery module voltage sensor that is reporting the lowest voltage.
Hybrid/EV Battery Voltage Sensors Average - Varies The Hybrid/EV battery pack contains many individual hybrid battery cells or modules. This parameter displays the average voltage measured at all of the cells/modules.
Hybrid/EV Electronics Coolant Pump Command - Varies This parameter displays the percent commanded coolant flow for the Hybrid/EV electronics coolant pump.
Hybrid/EV Electronics Coolant Pump Feedback - 45-55% This parameter displays the internal diagnostic status for the Hybrid/EV electronics coolant pump. A duty cycle of 45 to 55% indicates no internal pump faults detected.
Hybrid/EV Electronics Coolant Pump Speed - Varies This parameter displays the actual speed of the Hybrid/EV electronics coolant pump motor shaft.
Hybrid/EV Electronics Coolant Temperature - Varies This parameter displays the temperature of the coolant within the hybrid electronics cooling system.
Hybrid/EV Powertrain Control Module Request - No This parameter displays if the hybrid/EV powertrain control module (1) is requesting the contactors to be open.
Hybrid/EV/EV Battery Capacity - Varies This parameter displays the capacity of the hybrid/EV battery pack expressed in engineering data form.
Ignition 1 Signal - Varies This parameter displays the voltage monitored at the control module terminal connected to the Ignition 1 circuit.
Isolation Test Resistance - Varies Vehicles equipped with high voltage storage and propulsion capability are designed with both the positive and negative high voltage circuits isolated from the vehicle chassis. This parameter displays the amount of isolation observed when the Hybrid/EV battery pack last performed its isolation diagnostic test. This test may run at accessory wake up or immediately following key-off. The value will be set to zero whenever DTCs are cleared.
Maximum Hybrid/EV Battery Module Temperature - Varies The Hybrid/EV battery pack contains many individual battery cells or modules. This parameter displays the temperature of the battery module reporting the highest temperature.
Maximum Hybrid/EV Battery Module Voltage - Varies The Hybrid/EV battery pack contains many individual hybrid battery cells or modules. This parameter displays the maximum voltage measured at any of the cells/modules.
Minimum Hybrid/EV Battery Module Temperature - Varies The Hybrid/EV battery pack contains many individual battery cells or modules. This parameter displays the temperature of the battery module reporting the lowest temperature.
Minimum Hybrid/EV Battery Module Voltage - Varies The Hybrid/EV battery pack contains many individual hybrid battery cells or modules. This parameter displays the minimum voltage measured at any of the cells/modules.
Overtemperature - No This parameter displays if the system is commanding contactors open to protect them from overheating. The contactors will overheat if cycled too many times within a short amount of time.
Passenger Compartment Heater Power Limited - No This parameter displays if the electric power available to the passenger compartment heater power is at its limit.
Power Delivered to Electric A/C Compressor from Hybrid Battery Pack - Varies This parameter displays the electric power in kW commanded by the hybrid powertrain control module 2 to the A/C compressor in order for it to provide Hybrid/EV battery pack and/or passenger compartment cooling.
Power Delivered to Electric Passenger Compartment Heater from Hybrid/EV Battery Pack - Varies This parameter displays the electric power in kW commanded by the hybrid powertrain control module 2 to the passenger compartment heater in order for it to provide heat.
Power Requested by Electric A/C Compressor from Hybrid/EV Battery Pack - Varies This parameter displays the electric power in kW estimated by hybrid powertrain control module 2 necessary to provide Hybrid/EV battery pack and/or passenger compartment cooling.
Power Requested by Electric Passenger Compartment Heater from Hybrid/EV Battery Pack - Varies This parameter displays the electric power in kW estimated by hybrid powertrain control module 2 necessary to provide passenger compartment heating.
Power Mode - Run This parameter displays the status of the ignition switch.
Proximity Detection Circuit - Varies The proximity detection circuit detects the presence of the drive motor battery charge cord. This parameter displays the voltage monitored on the detection circuit.
Requested DC Charging Current - Varies This parameter displays the amount of DC charge current requested by the hybrid powertrain control module 2 of the off-vehicle DC charge station.
Shutdown Mode - No Shutdown Mode is the semi-operational state while a control module is turning off. Shutdown mode allows time for house-keeping tasks such as writing data to stored memory. This parameter displays if the module is in the process of shutting down.
Stuck Open - No This parameter displays the contactors are commanded open because the module has detected one or more of the high voltage contactors will not close.
Warm-Ups Since DTC Cleared - Varies This parameter displays the number of OBD defined warm-up cycles since the last time codes were cleared with a scan tool or, when applicable, with a 12V battery disconnect. A warm-up cycle occurs after the propulsion system has been active for 1000 consecutive seconds with run/crank ignition active.
Hybrid Powertrain Control Module 2 Scan Tool Output Controls

Output Control Description
A/C Compressor Speed This output control is used to vary the electric air conditioning compressor motor output speed.
Check High Voltage System Related DTCs
  • The hybrid powertrain control module 2 monitors for high voltage safety conditions. If these conditions are present the module will set DTCs and prevent high voltage enabling.
  • This output control identifies if the related DTCs have passed.
Clear Secured High Voltage DTCs
  • This output control is used to clear a latched high voltage (HV) lockout state.
  • The hybrid powertrain control modules 1 and 2 monitor for high voltage safety conditions such as airbag deploy events and certain HV system faults.
  • If these conditions are present either module may set a DTC and prevent HV enabling until after this Output Control is exercised.
  • NOTE:

    Performing a scan tool DTC Clear may clear the diagnostic that set the HV lockout state, but will not reset the lockout.

  • Always refer to Clear Secured High Voltage DTCs procedure in Hybrid/Energy Storage service information for the proper sequence of procedures required to reset a HV lockout state.
Cooling Fan Motor This output control is used to vary the coolant radiator cooling fan motor between 10% and 90%.
DC Charge Port Lock This output control is used to energize the M110 Charger Receptacle Lock Actuator which locks the charge cord to the vehicle.
Hybrid/EV Battery Contactors This output control is used to energize the high voltage contactors for diagnostic purposes. Refer to the applicable high voltage contactor diagnostic trouble code for setup and usage instructions.
Hybrid/EV Battery Negative Contactor This output control is used to energize the high voltage contactors for diagnostic purposes. Refer to the applicable high voltage contactor diagnostic trouble code for setup and usage instructions.
Hybrid/EV Battery Pack Active Cooling This output control is used to enable Active Cooling of the Hybrid/EV Battery Pack. The electric A/C compressor will be turned ON and the coolant control valve will be set to the chiller position allowing the air conditioning refrigerant to cool the hybrid/EV battery coolant.
Hybrid/EV Battery Pack Coolant Control Solenoid Valve This output control is used to energize the Q65 Hybrid/EV Battery Pack Coolant Control Valve. The valve has one fluid input port and three fluid output ports, identified as Radiator, Bypass, and Chiller. Bypass does not allow coolant to pass through either heat exchanger. The valve can be moved to several intermediate positions between Bypass and Chiller, for blended cooling of the hybrid/EV battery pack coolant for optimum efficiency.
Hybrid/EV Battery Pack Coolant Pump This output control is used to vary the coolant pump speed between 20% and 90%.
Hybrid/EV Battery Pack Coolant Pump Bleed Procedure This output control is used with the Drive Motor Battery Cooling System Draining and Filling procedure and the GE-47716 Van-N-Fill Coolant Refill Tool or its equivalent regional tool.
Hybrid/EV Battery Pack Heater Power This output control is used to energize the Battery Pack Heater. The output control is limited to 10%. Refer to DTC P1EC6.
Hybrid/EV Battery Pack Isolation Test
  • Vehicles equipped with high voltage storage and propulsion capability are designed with both the positive and negative high voltage circuits isolated from the vehicle chassis.
  • This output control commands the hybrid powertrain control module 2 to measure the isolation of the hybrid/EV battery pack
  • The following control limits apply:
    • All high voltage contactors are open
    • The vehicle power mode is OFF
Depress and hold the brake pedal while the vehicle power mode is OFF to wake up the modules prior to enabling this output control.
Hybrid/EV Battery Pack Precharge Transistor This output control is used to energize the high voltage contactors for diagnostic purposes. Refer to the applicable high voltage contactor diagnostic trouble code for setup and usage instructions.
Hybrid/EV Battery Positive Contactor This output control is used to energize the high voltage contactors for diagnostic purposes. Refer to the applicable high voltage contactor diagnostic trouble code for setup and usage instructions.
Hybrid/EV DC Charging Contactors This output control is used to energize the high voltage DC charge contactors for diagnostic purposes. Refer to the applicable high voltage contactor diagnostic trouble code for setup and usage instructions.
Hybrid/EV Electronics Coolant Pump This output control is used to vary the coolant pump speed between 20% and 90%.
Hybrid/EV Multifunction Contactor This output control is used to energize the high voltage contactors for diagnostic purposes. Refer to the applicable high voltage contactor diagnostic trouble code for setup and usage instructions.